Doppler Ultrasound Fetal Monitor YR02181

Manufacturer: Kalstein

Manufacturer: Kalstein

Product Description

10.2 inch large-screen color TFT display, digital display and waveform oscilloscopeof twins heart rate (FHR) and uterine contraction pressure (TOCO) value;Directly viewing 1:1 scale of display and print out waveform;7-wafer impulse ultrasound transducer, confugured with special HR self correlation reading algorithm to ensure correct and reliable fetal hear rate (FHR) measurement;Auto power failure protection and reliable rechargeable Li-ion battery can realize continual monitoring funciton.

  • 10.2″ Inch large-screen color TFT display, digital display and waveform oscilloscopeof twins heart rate (FHR) and uterine contraction pressure (TOCO) value;
  • Directly viewing 1:1 scale of display and print out waveform;
  • 7-wafer impulse ultrasound transducer, confugured with special HR self correlation reading algorithm to ensure correct and reliable fetal hear rate (FHR) measurement;
  • Auto power failure protection and reliable rechargeable Li-ion battery can realize continual monitoring funciton.
Model YR02181
Fetal heart rate
Method of measurement Ultrasound doppler
Measuring range 50-240 BPM
Measurement tolerance Less than ± 1 BPM
Scope of the fetal heart rate curve 50-240 BPM
Fetal heart rate numerical display oscilloscope 50-240 BPM
Ultrasound working frequency 2 MHz, 2.5 MHz
Ultrasound output intensity <5 mW / cm2
FOR CO
Method of measurement External measurement
Measuring range 0-100 unit
Numerical display range of uterine contraction pressure 0-100 unit
Non-linearity tolerance less than 10%
Auto-zero function Yes
General specifications
Fetal movement record
manual control button label
automatic identification of fetal movement
Display 10.2 “color TFT-LCD (800RGB” 480)
Event mark 9 available
Recording mode Thermal matrix printer
Recording paper 112mm x 100mm Folded Thermal Printing Paper
Paper feed speed 1,2,3cm / min 3 options
Audible and visual fetal heart rate alarm low limit 120 BPM, upper limit 160 BPM
Alarm activation time <3 s
Printer failure alarm Empty paper alarm
Output volume Speaker 2-3W Adjustable volume
Power supply AC: 100-240 V 50/60 Hz ± 1 Hz 40 VA
DC 14.4V / 2000mAh rechargeable Li-ion, continuous work> 4h
Security level Class l, type B
Size L296mm x W312 mm x H92 mm
Net working capacity Yes

 

Additional Information

Weight 6 kg
Dimensions 41,7 × 30,5 × 37,5 cm